Beijer-electronics SCOM Protocol EN Manuale Utente Pagina 34

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 131
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 33
Command Reference
34 Beijer Electronics, MAEN975
6.9 MCC_GAMMAVALUE (0x9D)
Gamma Value
Sets or queries the gamma value.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
Response Message (Acknowledge)
Maximum Lr for this Command
11
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x07 ADR
0x4D 0x43 0x43 LEN ICHKH 0x9D Param ICHKD
Param: ABSOLUTE
Value: 0”: Linear
1”: CRT
Type: One-digit ASCII-encoded hexadecimal number
Length: 1
Description: New gamma value
Param: RESET
Value: “R” or “r” (0x52 or 0x72)
Type: ASCII character
Length: 1
Description: Reset the gamma setting to an internally predefined value
Param: QUERY
Value: ?” (0x3F)
Type: ASCII character
Length: 1
Description: Query the current gamma value
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR
0x4D 0x43 0x43 LEN ICHKH 0x9D Param Ret ICHKD
Ret
Value: 0”: Linear
1”: CRT
Type: One-digit ASCII-encoded hexadecimal number
Length: 1
Description: Current gamma value
Vedere la pagina 33