Command Reference
Beijer Electronics, MAEN975 41
6.12 MCC_GREENLEVEL (0xB5)
Green Channel Level
Adjusts the level of the green channel.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x07 ADR
0x4D 0x43 0x43 LEN ICHKH 0xB5 Param ICHKD
Param: ABSOLUTE
Value: “00”: low...“FF”: high
Type: Two-digit ASCII-encoded hexadecimal number
Length: 2
Description: New value for the green channel
Param: INC
Value: “+” (0x2B)
Type: ASCII character
Length: 1
Description: Increment the current value of the green channel
Param: DEC
Value: “-” (0x2D)
Type: ASCII character
Length: 1
Description: Decrement the current value of the green channel
Param: RESET
Value: “R” or “r” (0x52 or 0x72)
Type: ASCII character
Length: 1
Description: Reset the value of the green channel to an internally
predefined value
Param: QUERY
Value: ?” (0x3F)
Type: ASCII character
Length: 1
Description: Query the current value of the green channel