Command Reference
Beijer Electronics, MAEN975 43
Example 3
Increment the current green channel level of monitor at address 0.7 (group 0, address
7):
Monitor at address 0.7 (group 0, address 7) has returned the new green channel level
191 (0xBD):
Example 4
Reset the green channel level of monitor at address 0.7 (group 0, address 7):
Monitor at address 0.7 (group 0, address 7) has returned the default green channel
level 128 (0x80):
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4D 0x43 0x43 0x02 0x1C 0xB5 0x2B 0x1F
0 1 2 3 4 5 6 7...10 11
0x06 0x07
0x4D 0x43 0x43 0x04 0x1B 0xB5 0x2B 0x42 0x46 0x97
0 1 2 3 4 5 6 7...8 9
0x07 0x07 0x4D 0x43 0x43 0x02 0x1C 0xB5 0x52 0xF8
0 1 2 3 4 5 6 7...10 11
0x06 0x07 0x4D 0x43 0x43 0x04 0x1B 0xB5 0x52 0x38 0x30 0x90