Command Reference
Beijer Electronics, MAEN975 25
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
MCC Sub-commands
All supported MCC sub-commands are described in the following sections.
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR 0x4D 0x43 0x43 LEN ICHKH SCMD Param Ret ICHKD
SCMD / Param
Video controller specific sub-command and parameter(s), sent with the
command stream
Ret
Data returned by the monitor, i.e. current value of the selected video
controller setting