Beijer-electronics AN-BEI-E2-038 Manuale Utente Pagina 9

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 11
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 8
APPLICATIONNOTEANBEIE2038 Date:15/02/12
ANBEIE2038ModbusRTUControlandRegisterMapping
9
AnalogandDigitalInputConfigurationswheninMODBUScontrolmode(P12=3or4)
BychangingthevalueinP15adjuststhefunctionalityofthecontrolterminalsasbelow:
P15 Digitalinput1(T2) Digitalinput2(T3) Digitalinput3(T4) Analoginput(T6) Comments
0..2,
4..5,
8..12
Open:Stop(disable)
Closed:Run(enable)
Noeffect Noeffect Noeffect
Runandstopcommands
givenviatheRS485linkand
Digitalinput1mustbe
closedforthedrivetorun.
3
1)
Open:Stop(disable)
Closed:Run(enable)
Open:Masterspeedref
Closed:Presetspeed1
Externaltripinput:
Open:Trip,Closed:Run
Noeffect
Connectexternalthermistor
typePT100orsimilarto
digitalinput3
6
1)
Open:Stop(disable)
Closed:Run(enable)
Open:Masterspeedref
Closed:Analoginput
Externaltripinput:
Open:Trip,Closed:Run
Analoginputreference
MasterSpeedRef‐ startand
stopcontrolledviaRS485.
KeypadSpeedRef‐drive
autorunsifdigitalinput1
closed,dependingonP31
setting
7
1)
Open:Stop(disable)
Closed:Run(enable)
Open:Masterspeedref
Closed:keypadspeedref
Externaltripinput:
Open:Trip,Closed:Run
Noeffect
ExampleWiring
AUTOMODBUSSpeed
HANDPresetSpeed1
AUTOMODBUSSpeed
HAND‐AnalogSpeedref
(potentiometer)
AUTOMODBUSSpeed
HAND KeypadSpeed ref (UP&DOWN
keysondrive)

Vedere la pagina 8
1 2 3 4 5 6 7 8 9 10 11