Beijer-electronics SCOM Protocol EN Manuale Utente Pagina 88

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 143
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 87
Command Reference
88 Elektronik-Systeme Lauer, MAEN976
Example
Read the predefined colour temperature of the monitor type MT223 NAV-230G at
address 0.7 (group 0, address 7), which is used in ECDIS mode:
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the predefined colour temperature in ECDIS mode is “USER” (0x04):
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4C 0x41 0x55 0x02 0x0D 0x01 0x17 0xFB
0 1 2 3 4 5 6 7 8
0x06 0x07
0x4C 0x41 0x55 0x01 0x0F 0x04 0xFB
Vedere la pagina 87
1 2 ... 83 84 85 86 87 88 89 90 91 92 93 ... 142 143

Commenti su questo manuale

Nessun commento