Command Reference
40 Elektronik-Systeme Lauer, MAEN976
6.10 MCC_GAMMAVALUE (0x9D)
Gamma Value
Sets or queries the gamma value.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: Not supported
Command Stream
Response Message (Acknowledge)
Maximum Lr for this Command
11
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x07 ADR 0x4D 0x43 0x43 LEN ICHKH 0x9D Param ICHKD
Param: ABSOLUTE
Value: 0”: Linear
1”: CRT
Type: One-digit ASCII-encoded hexadecimal number
Length: 1
Description: New gamma value
Param: RESET
Value: “R” or “r” (0x52 or 0x72)
Type: ASCII character
Length: 1
Description: Reset the gamma setting to an internally predefined value
Param: QUERY
Value: ?” (0x3F)
Type: ASCII character
Length: 1
Description: Query the current gamma value
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR 0x4D 0x43 0x43 LEN ICHKH 0x9D Param Ret ICHKD
Ret
Value: 0”: Linear
1”: CRT
Type: One-digit ASCII-encoded hexadecimal number
Length: 1
Description: Current gamma value