Command Reference
100 Elektronik-Systeme Lauer, MAEN976
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Read the digital input port configuration for the monitor at address 0.7 (group 0, ad-
dress 7):
According to the data returned by the monitor at address 0.7 (group 0, address 7),
command “Special functions 1” is assigned to the digital input port:
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4C 0x41 0x55 0x02 0x0D 0x01 0x21 0xDD
0 1 2 3 4 5 6 7 8
0x06 0x07
0x4C 0x41 0x55 0x01 0x0F 0x02 0xFD